Fire Alarm Systems & Integration
Code-disciplined fire alarm wiring, device installation, and integrated life-safety interfaces built to pass AHJ inspection.
At a Glance
AG Network Cabling supports commercial fire alarm installation and life-safety integration under California CSLB #1076251 (C-10 Electrical and C-7 Low Voltage). We coordinate engineered drawings, install fire-rated pathways and initiating/notification devices, wire access-control door release, elevator recall, and HVAC shutdown relays, and support AHJ acceptance testing to NFPA 72 and the 2025 California Fire Code.
Why Buyers Choose Disciplined Execution
Fire alarm delays hold up certificates of occupancy faster than almost any other trade. Missed relay interfaces to maglocks, elevator controllers, or smoke dampers force failed Authority Having Jurisdiction (AHJ) pre-tests and costly rework.
We coordinate closely with fire protection engineers, NICET-certified designers, and local fire marshals so pathways, CSFM-listed hardware, and integrated system triggers work together cleanly on test day.
Scope We Deliver
Fire Alarm Installation & Pathways
01- Fire-alarm power-limited (FPLP/FPLR) and pathway-survivability conduit installations per NEC Article 760
- Addressable fire alarm control units (UL 864 / CSFM-listed), smoke/heat detectors, pull stations, and horn/strobes
- Dedicated 120V primary power circuits installed under our C-10 license
Integrated Life-Safety Interfaces
02- Access control fail-safe door release and delayed-egress integration
- Elevator Phase I recall and shunt-trip coordination
- HVAC fan shutdown, smoke damper, and fire-sprinkler flow/tamper monitoring tie-ins
Plan Check & Acceptance Testing Support
03- Design coordination with licensed fire protection engineers or NICET-certified designers
- 100% pre-testing of initiating devices, notification circuits, and supervisory signals
- Support for AHJ final acceptance testing and NFPA 4 integrated system testing
How It Works: Survey to Turnover
1. On-Site Survey & Analysis
PHASE 01We walk the facility, inspect existing pathways, closets, and electrical capacity, and clarify schedule or occupancy constraints before pricing.
Site survey notesPathway & closet assessmentWritten scope and quote2. Pre-Construction & Submittals
PHASE 02We prepare product cut sheets, coordinate RFIs with the general contractor or IT lead, and align pathway routing with other trades.
Product submittals & cut sheetsRFI responsesShop drawings / port schedules3. Procurement & Staging
PHASE 03Materials are ordered to specification, staged cleanly, and verified against jobsite delivery windows and security protocols.
Bill of materials verificationDelivery & staging schedule4. Installation & Dressing
PHASE 04Field installation follows NEC, California Electrical Code, and TIA pathway rules with Velcro-dressed bundles and clear trade separation.
Daily progress logsIn-progress quality checks5. Testing & Commissioning
PHASE 05Every drop, fiber strand, circuit, or device is verified against applicable TIA, IEEE, or NFPA performance limits before turnover.
Certification test reportsCommissioning & punchlist sign-off6. Documentation & Closeout
PHASE 06We label infrastructure to ANSI/TIA-606-D conventions and hand over complete digital closeout packages for your facilities and IT teams.
TIA-606 labeling scheduleRedline as-builtsO&M manuals & owner training7. Ongoing Support
PHASE 07Post-turnover moves, adds, changes (MACs), troubleshooting, and preventive maintenance keep systems documented as your facility evolves.
Updated port mapsService tickets & maintenance records
Applicable Standards & Codes
| Standard / Code | What It Governs |
|---|---|
| NFPA 72 (2025) | National Fire Alarm and Signaling Code (installation, testing, survivability, Ch. 11 cybersecurity) |
| 2025 California Fire Code (Title 24 Part 9) | State fire-alarm, occupancy, and AHJ acceptance requirements |
| 2025 CEC / NEC Art. 760 | Fire alarm circuit wiring methods, power-limited separation, and Art. 760.25 |
| UL 864 & CSFM BML | Listed fire alarm control units and California State Fire Marshal equipment listing |
| NFPA 3 & NFPA 4 (2024) | Commissioning and integrated testing of interconnected fire/life-safety systems |
Deliverables at Turnover
- As-built device address maps and riser diagrams
- NFPA 72 Record of Completion documentation coordinated with the designer/engineer of record
- Pre-test sign-off checklist prior to AHJ witness testing
Testing & Verification
Every initiating device, notification appliance circuit, battery backup, and auxiliary relay (door release, HVAC, elevator) is pre-tested prior to Fire Marshal witness inspection.
Warranty & Licensing
Workmanship warranty terms and equipment manufacturer warranties are confirmed in your written proposal; licensing and subcontracting roles are clearly defined up front.
Applicable License: California CSLB #1076251 (C-10 Electrical)
How This Scope Adapts by Industry
Hospital fire alarm modifications coordinated with HCAI oversight, ICRA barriers, and phased clinical cutovers.
Why AG Network Cabling
Related Services
Access Control
Card and mobile-credential readers, controllers, electrified strikes and maglocks, gate entry, fire-alarm egress integration, and clean panel installation.
Electrical (C-10)
Licensed California C-10 commercial and IT-adjacent electrical work: dedicated server circuits, rack PDUs, panels, sub-panels, TI power, grounding, and code corrections.
Sound Masking & Paging
Open-office and clinical speech privacy sound masking, zoned emitter layouts, overhead paging, and VoIP or emergency priority override integration.
Security Cabling
Dedicated low-voltage cabling infrastructure for IP cameras, access control doors, intercoms, gates, and intrusion sensors with clean pathway separation.
Frequently Asked Questions
How does California licensing work for commercial fire alarm installations?
In California, electrical/fire alarm installation is performed under a C-10 Electrical license with CSFM-listed equipment and AHJ-approved plans. Where a project requires a dedicated fire alarm contractor or engineered stamp, we clearly define our role as prime or subcontractor during estimating.
Do you handle the tie-in between fire alarm panels and access-controlled doors?
Yes. Because AG installs both access control and C-10 electrical/fire-alarm wiring, we coordinate fail-safe maglock release relays cleanly so there is no gap between trades during Fire Marshal inspection.
Can you modify existing fire alarm devices during an office tenant improvement?
Yes. We relocate and add horn/strobes, smoke detectors, and pull stations to match revised architectural partitions and approved TI fire-alarm drawings.
Do you provide fire alarm design and plan-check submittals?
We coordinate design and plan-check submittals with qualified NICET-certified designers or licensed fire protection engineers as required by the local AHJ.
What is NFPA 4 integrated testing?
NFPA 4 governs testing the interaction between interconnected life-safety systems—such as verifying that a fire alarm trigger simultaneously releases maglocks, recalls elevators, and shuts down HVAC air handlers.
CA CSLB #1076251 · C-7 Low Voltage & C-10 Electrical
Ready to scope your project or send plans?
Upload drawings, specifications, or an Invitation to Bid, or call us to schedule a free on-site survey.