AG Network Cabling

CALIFORNIA CSLB #1076251 · C-7 LOW VOLTAGE & C-10 ELECTRICAL

Structured cabling, fiber, security, and electrical from one accountable contractor.

Headquartered in Los Angeles County and supporting national data center and multi-site programs, AG Network Cabling delivers organized, TIA-606 labeled infrastructure and licensed C-10 power with zero finger-pointing between trades.

ELEVATION · 42U MDF / DATA HALL CABINETTIA-942-C · 2025 CEC
OVERHEAD FIBER RACEWAY + LADDER RACKMPO-24 FIBER CASSETTESOS2 / OM4 · TIA-568.3-EPP-01A · CAT6A · TIA-606-D LABELEDCORE / ACCESS SWITCHESPoE++ 802.3bt · 10G/100G UPLINKSPP-02A · SECURITY & WAP DROPSVMS / NVR & ACCESS HEADENDNDAA §889 · UL 294 · VLAN ISOLATEDUPS + DEDICATED C-10 CIRCUITS20A/30A LOCKING · NEC ART. 645TIA-607-E / NEC 250 BONDING BUSBARC-7 LOW VOLTAGEFiber, Cat6A, AV, CCTVC-10 ELECTRICALPDUs, Panels, GroundingONE CONTRACTORCSLB #1076251VELCRODRESSED
Schematic: Unified C-7 + C-10 Rack ArchitectureZero Trade Handoff Friction
CA CSLB #1076251 (C-7 & C-10)One Accountable Team for Power & Low VoltageFree On-Site Survey & Written QuoteVerify Credentials →

LA & INLAND EMPIRE · ANSI/TIA-1005-A

High-Bay Wi-Fi & Multi-IDF Fiber Across 500k+ Sq Ft.

Armored OS2 fiber feeding column-mounted NEMA IDFs, directional aerial-lift WAP drops, dock WDR cameras, and yard LPR.

90m TIA RuleNEMA IDFsDock CCTV / LPR
Explore Warehousing & Logistics Scope
MDF / ERCORE SWITCHC-10 DEDICATEDOS2 / OM4 RISERFLOOR IDFTIA-606-DPoE++ 802.3btWi-Fi 6E/7 DUAL CAT6AWORKSTATION DROPSCONFERENCE / AV-IPSECURITY / CAMERA PoEMAX 90m PERMANENT LINK (ANSI/TIA-568.2-E)

CSI DIV 26 / 27 / 28 · NDAA §889

Compliant Infrastructure for Cities, Counties & Federal Sites.

Prevailing-wage readiness, NDAA FY2019 §889 & TAA hardware sourcing, FICAM/PIV access control, and 1-click Capability PDF.

CA CSLB #1076251NDAA §889 / TAAPrevailing Wage
Explore Government & Public Works Scope
SECURITY HEADENDVMS / NVR · ACCESS CTRLHARDENED CAMERA VLANNDAA §889 · UL 294IP DOME / PTZ / LPRONVIF · SHIELDED PoEFIRE ALARM RELEASENFPA 101 FAIL-SAFECARD / MOBILE / PIVFICAM / CBC 11B HEIGHTSTRIKE / MAGLOCK / REXCOMPOSITE DOOR CABLE

HCAI AWARE · ICRA CONTAINMENT · TIA-1179-A

ICRA-Disciplined Cabling & Life Safety for 24/7 Care.

High-density clinical drops, hospital fire-alarm integration, pharmacy access control, and ASTM E1130 speech privacy.

ICRA ContainmentHCAI / IORASTM E1130
Explore Healthcare Scope
FACU (UL 864)CSFM LISTED · NFPA 72NEC ART. 760 FPLP/FPLRC-10 PRIMARY POWERINITIATING LOOP (SMOKE / HEAT / PULL)NAC HORNS / STROBES / VOICE EVACNFPA 4 RELAYS: ACCESS RELEASE · ELEVATOR · HVACAHJ / HCAI / DSA ACCEPTANCE PRE-TEST

GREATER LOS ANGELES · VIP DISCRETION

Low-Loss OS2 / OM5 Fiber for 4K/8K Stages & Control Centers.

Edit-bay SAN backbones, broadcast-clean AVIXA F502.01 racks, concealed lifts, and NDA-disciplined dark-day builds.

40G/100G FiberControl CentersNDA Discretion
Explore Studios & Entertainment Scope
ROOM & ACOUSTIC LAYOUTDISCAS / DSPANSI/AVIXA F502.01 AV RACKConcealed Mounts · Automated Lifts · C-10 PowerASTM E1130 SOUND MASKINGZoned Emitters · Speech Privacy · Overhead PagingVoIP & E911 COMPLIANCEKari's Law Direct 911 · RAY BAUM'S Dispatchable Loc.

OCCUPIED LUXURY HOTELS · PHASED TURNS

Quiet Guest-Room Cabling, Wi-Fi & Concealed Venue AV.

Floor-by-floor renovation pacing, concealed TV mounts and lifts, discreet lobby CCTV, and room-level E911 VoIP.

Floor-by-FloorConcealed LiftsVIP Discretion
Explore Hospitality Scope
/01SURVEY & ITBCSI Div 26/27/28/02SUBMITTALSNDAA / Cut Sheets/03C-7 + C-10 BUILDPrevailing Wage / MOP/04TURNOVERTests + As-BuiltsONE ACCOUNTABLE TEAM · FREE ON-SITE SURVEY · DOCUMENTED CLOSEOUT

FAST-TRACK TI · 2025 CEC ABATEMENT

Move-In-Ready Cat6A, Boardroom AV & NEC Closet Rehab.

Workstation & PoE++ drops, suite mobile access, sound masking, and lease-surrender abandoned cable removal.

Cat6A / PoE++NEC §722.25100% Certified
Explore Office & CRE Portfolios Scope
ANSI/TIA-1152-A CERTIFICATION SWEEP (1–500 MHz · CAT6A PERMANENT LINK)100% PASSMEASURED HEADROOMTIA-568.2-E LIMITWIREMAP · LENGTH · INSERTION LOSS · NEXT · PSNEXT · ACR-F · DCRU · RETURN LOSS

Our Capabilities · 16 Confirmed Services

Five Disciplines. One Accountable License.

Filter Full Directory

High-density MPO/MTP data halls, Cat6A horizontal drops, fusion splicing, testing & closet rehab.

/0.1CSI DIV 27 · CA C-7
CORE-ALIGNMENT FUSION SPLICING · TIER 1 OLTS & TIER 2 OTDR TRACESPLICE LOSS < 0.05 dB TYPICAL0m LAUNCHSPLICE EVENT VERIFIEDPASS · TIA-526-7 / 526-14

Dedicated IT & server rack circuits, dual A/B PDUs, panels, sub-panels & TIA-607-E grounding.

/0.2CSI DIV 26 · CA C-10
C-10 SUB-PANEL20A/30A LOCKING RACK PDUs (A/B)DEDICATED UPS & SECURITY CIRCUITSNEC ART. 250 / TIA-607-E TMGB BUSBAR2025 CALIFORNIA ELECTRICAL CODE (TITLE 24 PART 3) · NFPA 70E LOTO SAFETY

NDAA §889 IP surveillance, card/PIV access control, electrified hardware & NFPA 72 fire integration.

/0.3CSI DIV 28 · C-7 & C-10
SECURITY HEADENDVMS / NVR · ACCESS CTRLHARDENED CAMERA VLANNDAA §889 · UL 294IP DOME / PTZ / LPRONVIF · SHIELDED PoEFIRE ALARM RELEASENFPA 101 FAIL-SAFECARD / MOBILE / PIVFICAM / CBC 11B HEIGHTSTRIKE / MAGLOCK / REXCOMPOSITE DOOR CABLE

Executive boardrooms, concealed display lifts, control centers, ASTM E1130 masking & E911 VoIP.

/0.4CSI DIV 27 · AVIXA
ROOM & ACOUSTIC LAYOUTDISCAS / DSPANSI/AVIXA F502.01 AV RACKConcealed Mounts · Automated Lifts · C-10 PowerASTM E1130 SOUND MASKINGZoned Emitters · Speech Privacy · Overhead PagingVoIP & E911 COMPLIANCEKari's Law Direct 911 · RAY BAUM'S Dispatchable Loc.

California prevailing-wage public works, ongoing MACs, urgent fiber repair & start-up commissioning.

/0.5GOV · GC · LIFECYCLE
/01SURVEY & ITBCSI Div 26/27/28/02SUBMITTALSNDAA / Cut Sheets/03C-7 + C-10 BUILDPrevailing Wage / MOP/04TURNOVERTests + As-BuiltsONE ACCOUNTABLE TEAM · FREE ON-SITE SURVEY · DOCUMENTED CLOSEOUT

Full-Stack Physical Layer

From C-10 Electrical Power to Certified Endpoints

Instead of coordinating three subcontractors across Division 26, Division 27, and Division 28, AG delivers the entire stack under one licensed schedule.

View CSI Div 26 / 27 / 28 Matrix →
AG UNIFIED PHYSICAL-LAYER ARCHITECTURE
C-10 POWER · PDUs · TIA-607OS2 / OM4 / MPO-24 BACKBONE · FUSION SPLICINGTIA-569FACILITY CORECAT6A / Wi-FiNDAA CCTVACCESS / UL 294AV / NFPA 72TIA-1152-ACERTIFIEDOLTS / OTDRFIBER LOGSTIA-606-DLABELINGAS-BUILTS& O&M BINDER04 · ENDPOINT SYSTEMSAccess, CCTV, AV, Wi-Fi, VoIP02 · FIBER & MDF COREMPO-24, Fusion Splicing, Racks03 · PATHWAYS & CAT6ALadder Rack, Velcro, Firestopping01 · C-10 ELECTRICAL BASEPanels, PDUs, Grounding (NEC 250)
Single-source physical infrastructure stack under California CSLB #1076251Survey → Submittals → Build → Certify → Support

The AG Standard

Work built neat enough to photograph

Tangled ceilings and unlabelled patch panels slow down every IT upgrade and violate 2025 California Electrical Code abandoned-cable rules. We dress every bundle in Velcro, label to ANSI/TIA-606-D, and test 100% of links drop-by-drop.

  • One team for C-7 low voltage and C-10 electrical circuits
  • Hook-and-loop Velcro dressing — zero zip-tie pinching
  • Discreet execution in luxury hotels, clinics, and live data halls
See Our Full QA & Labeling Standard

Interactive Craftsmanship Comparison

Legacy Closet Abatement → The AG Standard

Drag slider to inspect
AFTER: THE AG STANDARD (TIA-606-D · VELCRO · TESTED)100% PASS CERTIFIED
PATCH PANEL 01 · ANSI/TIA-606-D MACHINE LABELEDMANAGED PoE++ SWITCH 01 · RIGHT-SIZED PATCH CORDSPATCH PANEL 02 · ANSI/TIA-606-D MACHINE LABELEDMANAGED PoE++ SWITCH 02 · RIGHT-SIZED PATCH CORDS
BEFORE: UNLABELLED LEGACY CLOSET (NEC §722.25 / §800.25 RISK)ABANDONED CABLE LOAD
After (AG)

CA CSLB #1076251 · C-7 Low Voltage & C-10 Electrical

Ready to scope your project or send plans?

Upload drawings, specifications, or an Invitation to Bid, or call us to schedule a free on-site survey.